Symptom: heater fan motor stopped working in cold weather.1

Diagnostic step. A direct electrical bypass test — powering the fan motor via the cigarette lighter circuit — temporarily restored function. This indicates the motor itself is likely still functional; the fault is in the control circuit feeding it, not the motor.123

Likely cause: the heater regulator/resistor (rheostat) has burned out or failed — this component controls fan speed and sits between the switch and the motor. Part: "реостат отопителя резистор" GV7D61B15.45

Fix: replace the heater resistor/regulator module — not the fan motor itself, since the motor tested functional via the bypass.45

Sources

This page is compiled from 5 community messages. Every fact carries a numbered reference to its original author and message.

Last updated: 2026-10-29


  1. Василий Егоров (964885990) · FAW X80 🚘🛠🛞 · 2024-12-19 · original message · ru ↩↩

  2. Unknown (uid 7612989230) (7612989230) · FAW X80 🚘🛠🛞 · 2024-12-19 · original message · ru ↩

  3. Василий Егоров (964885990) · FAW X80 🚘🛠🛞 · 2024-12-19 · original message · ru ↩

  4. 1706 (6158563221) · FAW X80 🚘🛠🛞 · 2024-12-19 · original message · ru ↩↩

  5. Эдуард Янонис (1292719479) · FAW X80 🚘🛠🛞 · 2024-12-19 · original message · ru ↩↩